How to install & turn on a water softener; free water softener manuals online. INSTALLATION of WATER SOFTENERS - CONTENTS: How Water Softeners Are Hooked Up to Building Plumbing Pipes & Electrical Wiring. Water Softener Parts, Valves, and Water Filters Fleck, GE Osmonics Autotrol, Sears / North Star and other brands. How to Connect Water Softener Water Piping Input & Output Water Lines & how to route & connect water conditioner regeneration cycle drain, salt tank, controls. POST a QUESTION or READ FAQs about how water softeners are installed: location, plumbing, wiring connections, drain connections & where to obtain installation & operation manuals REFERENCESInspect. APedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website. The calcite and/or NS-Mix will diminish in volume over time as it raises pH and adds hardness to the water supply. Our maintenance instructions state that mineral (NS. All the parts that go into the Autotrol 255 Valve Body, plus orings to tank adapter. Autotrol 255 Upper Valve Module with 740 LOGIX Timer Assembly,12 volt transformer. It may surprise you to learn that one of the easiest and most cost effective improvements you can make to your home and lifestyle can be had by installing one. How to clean & or sanitize a water softener or water conditioner Check the water conditioner brine tank for salt crusting Check the water softener brine tank for dirt. How to install a water softener or water conditioner or water treatment system. How Water Softeners Are Hooked Up to Building Plumbing Pipes & Electrical Wirin How to. As an eco-minded homeowner, you may find yourself feeling a bit concerned about using a traditional salt-based water softener in your home. After all, there are. How to install or . This article explains how to hook up a water softener or water conditioner. We describe the piping connections for water in and out of the water softener, water softener bypass valves for maintenance, and water softener drain hookups. This article series explains how water softeners and similar water conditioners work, types of water softeners, and the basics of what water softener controls are present and what they do, how water softeners should be installed, maintained, cleaned, and adjusted. Green links show where you are. Usually these two pieces are separate (except in some older manually operated water softeners), but they are installed side- by- side. Our photo of a water conditioner installation at left shows a Kinetico Mach Series water conditioner system installed in a Dutchess County New York home. AUTOTROL® 255 VALVE / 400 SERIES CONTROLS SERVICE MANUAL ©2012 Pentair Residential Filtration, LLC Tech Support: 800.279.9404 www.pentairaqua.com/pro. Autotrol 255 - 460I Digital Metered Water Softener, Home Water Softener, Buy, Compare. Retrouvez toutes les discothèque Marseille et se retrouver dans les plus grandes soirées en discothèque à Marseille. Where space is really tight, we sometimes see the larger brine tank installed somewhere else not right next to the water softener, but of course connected to it by its flexible plastic tubing. Article Contents. Guide to Connecting A Water Softener Water Piping or Input and Output Water Lines. Since it's usually preferable to treat all of the building water supply with a water conditioner (this helps protect pipes from mineral- clogging by hard water), the water conditioner is usually placed as close as possible to where water enters the building. Most installers place the water softener near other water equipment in the building such as close to an indoor pump and water pressure tank, or where municipal water is supplied, close to where the water supply enters the building. Be sure to consult the specific manual for your own water softener brand and model for correct hookup details for your own equipment. The water softener is piped . For example, dirt or silt in a water supply can quickly coat the bulb in a UV light bacterial treatment device on a private water supply system. Incoming water is connected to the . This specific chart is from a Culligan System 1. Water Conditioner installation manual. Be sure to check your own equipment's installation manual. When the water softener goes through a regeneration cycle it will bypass the building water supply, often automatically, so that water stops passing through the equipment's treatment system pump water into the separate brine tank (salt tank) where it dissolves salt pump new salty water backwards through the resin tank or treatment tank where the process removes other minerals from the treatment tank, sending this product out through a (usually plastic) drain tube to a building drain. Other water conditioner manufacturers such as Autotrol specify other drain line connection details. The ideal water conditioner location is above (higher than) and not more than 2. Use 1/2- inch plastic tubing between the water conditioner drain hookup on the equipment and the drain. The ideal location for a water conditioner (or softener) is also in an area protected from freezing, protected from mechanical damage (don't run into it when pulling a car into the garage), and at a location convenient for connection to building water supply piping and electrical hookups. Usually we locate the water conditioner as close as possible to the point of water entry into the building so that we protect as much of the building plumbing system as possible from mineral clogging. Increase the water softener drain line diameter from 1/2- inch to 3/4- inch diameter for runs of more than 2. For elevated water conditioner drain lines, provided that incoming water pressure is at least 4. You can elevate the water conditioner drain line another two feet for every 1. For example if your water pressure is always 5. Watch out: Use a Siphon Trap: for elevated water conditioner drain lines emptying into a drain below the level of the control valve (that's where the drain line connects to the water softener), make a 7- inch loop in the plastic drain line such that the bottom of the drain line loop is level with the drain line connection point (at the water softener). The loop should provide an adequate anti- siphon trap. Without this detail, after a water softener regen cycle when the drain line is filled, the drain can continue to siphon- drain water out of the water softener. Warnings: Avoid These Water Conditioner Drain Connection Mistakes. Connect your water conditioner drain line to a building drain or to a separate graywater drain feeding drywell, but do not simply spill water conditioner drainage onto the ground surface such as is shown in our photo shown above - a water softener drain hose simply spurts out through the building exterior wall and onto the ground surface. Doing so violates plumbing and sanitary code in most jurisdictions (and invites basement or crawl space leakage too). Watch out: be sure that the water softener drain connection is made following the manufacturer's instructions . If you are using soft flexible tubing to connect your water conditioner to a drain line it's easy to crimp the line at a sharp bend or where it is stapled to a building support. A crimped water conditioner drain will interfere with proper backwash/regeneration cycling of your equipment. Watch out: Use an air gap: for elevated water conditioner drain lines that empty into an overhead sewer pipe or waste pipe you should use a sink- type trap for the connection (that is provide an air gap to avoid back- contamination of the equipment). Watch out: Never connect the water softener drain line directly to a sewer drain (that is by an air- tight connection such as shown at left). Doing so invites sewage and bacterial back- contamination into the building water supply system, especially if a sewer line backup occurs. See CROSS CONNECTIONS, PLUMBING. Connecting Water Softener Electrical Power. The water softener also needs to be plugged- in to an electrical outlet to power the equipment control. See Steps in Starting Up A New or Newly- Installed Water Softener for details. Setting up the Water Softener & Setting Its Controls. You'll need to set the water conditioner's clock to the proper time (and day on some models) and you may need to set the water softener controls that determine the frequency of regeneration and the salt dose. See SOFTENER ADJUSTMENT & CONTROLS. Steps in Starting Up A New or Newly- Installed Water Softener. The following advice is adapted from water softener installation manuals from Culligan and other water conditioner manufacturers. For new water conditioners: The water conditioner start- up procedure here is appropriate when you are installing a new water conditioner system or a new water conditioner media tank. Watch out: as Culligan's manuals point out about new water conditioners,A sanitizing agent has been added to the conditioner tank . This sanitizing agent must be flushed out before the unit is placed into service, by initiating a recharge cycle using the steps outlined below. Plug in the power cord: Check that the water conditioner timer or control is in the . If necessary you can use a three- prong to two- prong adapter to connect to a two- prong electrical receptacle, but be sure that that receptacle is itself grounded. In general, a three- prong to two- prong electrical outlet adapter includes a green metal tab with a hole in it that is used to make a proper connection to the electrical grounding system. The screw in the center of the cover plate for the electrical receptacle is removed and reinserted through the green tab so that the adapter is secured in place and a ground connection is made. We recommend that you ask your electrician to install a grounded, three- prong electrical receptacle in that location as soon as convenient. Set the water conditioner controls: set the timer to the correct time of day, time of recharge, recharge frequency, and set the . See SOFTENER ADJUSTMENT & CONTROLS for details. Open the bypass valve: with the controls set for normal service, slowly open the water inlet valve or slowly open the bypass valve if it was in the closed or . On a Culligan water softener this means push slowly on the blue knob on the bypass valve to put the unit into service. Allow water to fill the resin tank. Perform a water softener regeneration cycle. On a typical Culligan model this may mean rotating the cam that carries the ? If hard, untreated water entered the building's hot water tank while the water softener was on bypass or turned off, then you should drain and refill the hot water tank. Watch out. Be sure that the water heater is turned off before and during drainage and refill. List of Free Water Softener & Water Conditioner Installation Manuals. Watch out: because water softener and other water conditioner equipment models vary in features and functions, they also vary in their exact installation requirements. You should have or obtain the installation, operation, and maintenance manual for your own brand and model of water softener. Most water softener owners manuals include detailed installation instructions and also a table of recommended settings. On this Autotrol water conditioner you can specify the time of regeneration (factory is set to 2: 0. AM) to be sure it's running at a time when you are not using water in the building.?
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
August 2017
Categories |